The inspection report details the replacement of the ammonia converter bottom forging block and inlet cold shot piping during Turnaround 2023 due to significant cracking and leakage issues. The new components were successfully installed, and subsequent non-destructive testing showed satisfactory results. Recommendations include inspecting remaining piping and the bottom forging in the next Turnaround scheduled for 2026.