Radiographic Test Procedure Overview by Eduard Abastillas is a document available to read on EtoBox.

This document provides procedures for performing radiographic testing at Bangladesh Industrial X-Ray. It outlines requirements for personnel qualifications, surface preparation, backscatter radiation, and acceptable radiation sources. Personnel must be qualified to at least Level II and have annual vision tests. Welds must be visually inspected before testing and have surface irregularities removed. Tests will use Iridium-192 or Selenium-75 radiation sources up to 30 Ci in strength, subject to regulatory li

Author
Eduard Abastillas
Language
EN