Opening book details…
Can I read Surface chemical analysis -- Auger electron spectroscopy and X-ray photoelectron spectroscopy -- Methods used to determine peak intensities and information required when reporting results on EtoBox?
Surface chemical analysis -- Auger electron spectroscopy and X-ray photoelectron spectroscopy -- Methods used to determine peak intensities and information required when reporting results by ISO is a reference work available to read on EtoBox.
What is Surface chemical analysis -- Auger electron spectroscopy and X-ray photoelectron spectroscopy -- Methods used to determine peak intensities and information required when reporting results about?
Foreword 0 Introduction 0 1 Scope 0 2 Normative references 0 3 Terms and definitions 0 4 Symbols and abbreviated terms 0 5 Methods for peak-intensity determination — direct spectrum 0 5.1 General 0 5.2 Selection and subtraction of an inelastic background 0 5.3 Measurement of peak intensity 0 5.3.1 Measurement of peak height 0 5.3.2 Measurement of peak area 0 5.4 Measurement of a peak intensity with computer software 0 5.5 Measurement of peak intensities for a spectrum with overlapping peaks 0 5.6 Uncertainty in measurement of peak area 0 6 Methods for peak intensity determination — Auger-electron differential spectrum 0 6.1 General 0 6.2 Measurement of Auger-electron differential intensity 0 6.3 Uncertainties in measurement of Auger-electron differential intensity 0 7 Reporting of methods used to measure peak intensities 0 7.1 General requirements 0 7.2 Methods used to determine peak intensities in direct spectra 0 7.2.1 Intensity measurement for a single peak, as described in 5.2 and 5.3 0 7.2.2 Intensity measurements from peak fitting, as described in 5.4 and 5.5 0 7.3 Methods used to obtain and determine peak intensities in Auger-electron differential spectra 0 7.3.1 Method us
Who reads Surface chemical analysis -- Auger electron spectroscopy and X-ray photoelectron spectroscopy -- Methods used to determine peak intensities and information required when reporting results?
It is typically read by working professionals who need an authoritative practice reference.
Common subject areas: medicine, law, business, engineering.
- Author
- ISO
- Language
- EN
- Category
- reference
More by ISO
Similar books
- Surface Chemical Analysis -- Electron Spectroscopies -- Minimum Reporting Requirements for Peak Fitting in X-ray Photoelectron Spectroscopy — ISO/TC 201/SC 7 Electron spectroscopies (2015)
- Surface Chemical Analysis. Auger Electron Spectroscopy. Reporting of Methods Used for Charge Control and Charge Correction. — British Standards Institute Staff (2010)
- Surface Chemical Analysis -- Auger Electron Spectroscopy and X-ray Photoelectron Spectroscopy -- Guide to the Use of Experimentally Determined Relative Sensitivity Factors for the Quantitative Analysis of Homogeneous Materials
- Surface Chemical Analysis. Auger Electron Spectroscopy and X-ray Photoelectron Spectroscopy. Determination of Lateral Resolution. — British Standards Institute Staff (2010)
- Surface Chemical Analysis -- X-ray Photoelectron Spectroscopy -- Reporting of Results of Thin-film Analysis — ISO/TC 201/SC 7 Electron spectroscopies (2013)
- Surface Chemical Analysis -- X-ray Photoelectron Spectroscopy -- Estimating and Reporting Detection Limits for Elements in Homogeneous Materials — ISO