Opening book details…
Can I read VE Pump Pre-Stroke Adjustment Guide on EtoBox?
VE Pump Pre-Stroke Adjustment Guide by Anonymous wpUyixsj is a document available to read on EtoBox.
What is VE Pump Pre-Stroke Adjustment Guide about?
This service bulletin provides instructions for adjusting the pre-stroke of VE type fuel injection pumps used on various Toyota engines. The pre-stroke adjustment accounts for an annual groove cut into the plunger to improve fuel intake efficiency. Technicians are to use special tools like an inlet adaptor and plunger stroke gauge to set the pre-stroke by measuring bubbles that appear on the plunger surface when air is applied through the adaptor. The bulletin lists reference pre-stroke values and instructi
- Author
- Anonymous wpUyixsj
- Language
- EN