About this document
Welded Connection Shear Force Analysis by Evonne Lee is a document available to read on EtoBox.
The document outlines the calculations for welded connections of various steel sections, including RHS and angle sections, with specified shear forces and weld sizes. It details the direct shear calculations, weld capacities, and checks for compliance with safety standards. The document emphasizes the need for a minimum weld size of 6mm for connections involving a 5mm thick steel plate.
- Author
- Evonne Lee
- Language
- EN