RFT Procedure for Heat Exchanger Tubes by vikram is a document available to read on EtoBox.

This document outlines the procedure for remote field testing of heat exchanger tubes using an Olympus MS 5800 system. Key steps include: 1) Cleaning tubes to remove deposits before testing. 2) Using a probe with an exciter coil and dual pickup coils to emit and detect electromagnetic fields. Changes in phase and amplitude indicate wall thickness changes. 3) Calibrating and verifying the system using a reference standard. Recording data, settings and interpretations. 4) Evaluating data using flaw cha