Skip to content

Opening book details…

Can I read Comparing the Accuracy of the Kane, Barrett Universal II, Hill-Radial Basis Function, Emmetropia Verifying Optical, and Ladas Super Formula Intraocular Lens Power Calculation Formulas on EtoBox?

Comparing the Accuracy of the Kane, Barrett Universal II, Hill-Radial Basis Function, Emmetropia Verifying Optical, and Ladas Super Formula Intraocular Lens Power Calculation Formulas by Majid Moshirfar; Christian A Sulit; Alex Brown; Chase Irwin; Yasmyne C Ronquillo; Phillip C Hoopes is a Medicine article available to read on EtoBox.

What is Comparing the Accuracy of the Kane, Barrett Universal II, Hill-Radial Basis Function, Emmetropia Verifying Optical, and Ladas Super Formula Intraocular Lens Power Calculation Formulas about?

## Purpose To assess the accuracy of five new-generation intraocular lens (IOL) power formulas: Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO) Formula, Hill-Radial Basis Function (Hill-RBF), Kane Formula, and Ladas Super Formula (LSF). ## Patients and Methods This is a retrospective single-surgeon study from a refractive clinic and clinical research center in Draper, UT, USA. The primary outcome measures were mean absolute error (MAE) and median absolute error (MedAE). Secondary outcome measures were the standard deviation (SD) of each formula’s refractive prediction errors (RPE) and the percentage of eyes within ±0.50D. Refractive predictions were compared to the postoperative spherical equivalent to determine the RPE for each formula. RPEs were optimized, and MAE, MedAE, SD of the AME, and percent of eyes achieving RPEs within the specified ranges of ±0.125 D, ±0.25 D, ±0.50 D, ±0.75 D, ±1.0 D were calculated. Subgroup analysis between different axial lengths was attempted but yielded insufficient statistical power to draw meaningful conclusions. ## Results A total of 103 eyes of 103 patients were included in our study after applying inclusion and exclusion crite

Who reads Comparing the Accuracy of the Kane, Barrett Universal II, Hill-Radial Basis Function, Emmetropia Verifying Optical, and Ladas Super Formula Intraocular Lens Power Calculation Formulas?

It is typically read by researchers, students, and practitioners in Medicine.

Author
Majid Moshirfar; Christian A Sulit; Alex Brown; Chase Irwin; Yasmyne C Ronquillo; Phillip C Hoopes
Publisher
Informa UK Limited
Published
2023
Language
EN
Field
Medicine (Health Sciences)

More by Majid Moshirfar; Christian A Sulit; Alex Brown; Chase Irwin; Yasmyne C Ronquillo; Phillip C Hoopes

Browse all works by Majid Moshirfar; Christian A Sulit; Alex Brown; Chase Irwin; Yasmyne C Ronquillo; Phillip C Hoopes