About this document
Blind Flange Thickness Calculation Guide by widnu wirasetia is a document available to read on EtoBox.
The document outlines the calculation for a blind flange using material A36 with a specified SMYS of 36,000 psi. It details the allowable stress, pipe dimensions, design pressure, hydrotest pressure, and required thickness calculations, resulting in a total minimum thickness of 85.98 mm. The calculations incorporate factors such as joint efficiency and corrosion allowance.