Opening book details…
Can I read Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware. Fire resistance of hinged and pivoted metal framed glazed doorsets and openable windows on EtoBox?
Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware. Fire resistance of hinged and pivoted metal framed glazed doorsets and openable windows by British Standards Institute Staff is a reference work available to read on EtoBox.
What is Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware. Fire resistance of hinged and pivoted metal framed glazed doorsets and openable windows about?
This standard BS EN 15269-5:2014+A1:2016 Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware is classified in these ICS categories:. 13.220.50 Fire-resistance of building materials and elements. 91.060.50 Doors and windows. This European Standard covers hinged and pivoted steel (any kind) and aluminium based framed, glazed doorsets or openable windows. This European Standard prescribes the methodology for extending the application of test results obtained from resistance to fire test(s) conducted in accordance with EN 1634-1. Subject to the completion of the appropriate test or tests selected from those identified in Clause 4 the extended application may cover all or some of the following examples:. integrity (E), integrity/radiation (EW) or integrity/insulation (EI1 or EI2) classifications;. doorsets and openable windows;. door / window leaf (leaves);. glazing and non-glazed panels in doorset and openable window;. items of building hardware;. decorative finishes;. intumescent, smoke, draught or acoustic seals;. alternative supporting construction(s).
Who reads Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware. Fire resistance of hinged and pivoted metal framed glazed doorsets and openable windows?
It is typically read by working professionals who need an authoritative practice reference.
Common subject areas: medicine, law, business, engineering.
- Author
- British Standards Institute Staff
- Publisher
- BSI British Standards Institution
- Published
- 2016
- Language
- EN
- ISBN
- 9780580878992
- Category
- reference
More by British Standards Institute Staff
Browse all works by British Standards Institute Staff
Similar books
- Fire Resistance and Smoke Control Tests for Door, Shutter and Openable Window Assemblies and Elements of Building Hardware. Fire Resistance Characterisation Test for Elements of Building Hardware — 标准分享网 (2008)
- Fire Resistance and Smoke Control Tests for Door and Shutter Assemblies, Openable Windows and Elements of Building Hardware. Smoke Control Test for Door and Shutter Assemblies — British Standards Institute Staff (2007)
- Fire Tests. Smoke Control Door and Shutter Assemblies. Commentary on Test Method and Test Data Application — BSB (1999)
- Fire Resistance Tests. Elements of Building Construction. Glazed Elements. — British Standards Institute Staff (2004)
- Extended Application of Test Results for Fire Resistance And/or Smoke Control for Door, Shutter and Openable Window Assemblies, Including Their Elements of Building Hardware. Fire Resistance for Operable Fabric Curtains — The British Standards Institution (2018)
- Fire-resistance Tests -- Door and Shutter Assemblies — ISO/TC 92/SC 2 Fire containment (2007)