Wilfley Wcd4 Duplex Stainless Steel Vs 904l Austenitic Stainless Steel by lutfi_ismail is a document available to read on EtoBox.
The document compares the wear resistance of WCD4 duplex stainless steel and 904L austenitic stainless steel. Tests using a pin-on-disk apparatus found the wear groove in WCD4 was smoother and narrower, while 904L showed a wider groove with circular scratches. Data analysis determined WCD4 has a 1,680% increase in wear resistance over 904L, demonstrating it is superior for pumping applications with corrosive and erosive wear.