Can I read BOP Control Unit Sizing and Design on EtoBox?

BOP Control Unit Sizing and Design by Ajay Vikram Singh is a document available to read on EtoBox.

What is BOP Control Unit Sizing and Design about?

The document summarizes the sizing of a control system for a 3000 PSI surface BOP stack according to API 16D standards. It determines that 8 accumulator bottles each with a capacity of 13.7 gallons and charged to 3000 PSIG are needed to provide a minimum usable liquid volume of 72.71 gallons under condition 1 and 36.18 gallons under condition 2. This meets the functional volume requirement of 33.59 gallons. A minimum reservoir capacity of 167.1 gallons is also required.

Author
Ajay Vikram Singh
Language
EN