Emergency Fire Pump Requirements on Ships by Prince Kumar Jha is a document available to read on EtoBox.
This document summarizes requirements for emergency fire pumps and international shore connections on cargo and passenger ships. The emergency fire pump must have an independent power source and seawater connection located outside the space containing the main fire pumps. It must be able to supply at least 40% of the total required fire pump capacity. Ships over 500 gross tons are also required to have international shore firefighting connections on either side to allow external fire hoses to be connected.