The document details a calculation for condensing steam in a power plant condenser at 30°C using cooling water from a lake. It provides the necessary formulas and values to determine the mass flow rate of cooling water, which is 32.5 kg/s, and the rate of condensation of steam, which is 0.45 kg/s. Key parameters include the heat transfer coefficient, surface area, and specific heat of water.