Use of Balloon Aortic Valvuloplasty to Size the Aortic Annulus Before Implantation of a Balloon-Expandable Transcatheter Heart Valve by Vasilis C. Babaliaros; Zahid Junagadhwalla; Stamatios Lerakis; Vinod Thourani; David Liff; Edward Chen; Thomas Vassiliades; Clay Chappell; Nathan Gross; Ateet Patel; Sharon Howell; Jacob T. Green; Emir Veledar; Robert Guyton; Peter C. Block is a Medicine article available to read on EtoBox.

What is Use of Balloon Aortic Valvuloplasty to Size the Aortic Annulus Before Implantation of a Balloon-Expandable Transcatheter Heart Valve about?

## Objectives: Our aim was to describe the use of balloon aortic valvuloplasty (bav) to select proper transcatheter heart valve (thv) size. ## Background: Transesophageal echocardiogram (tee) measurement alone of the aortic annulus may not be adequate to select a thv size. bav can more accurately size the aortic annulus. we report our experience using this strategy in patients undergoing thv implantation. ## Methods: Twenty-seven patients underwent sizing of the aortic annulus by bav and tee. we implanted the minimal thv size that was greater than the annulus measured by bav. ## Results: The annulus measured by tee was 21.3 +/- 1.6 mm and by bav was 22.6 +/- 1.8 mm (p < 0.001). the number of balloon inflations was 2.7 +/- 0.7 (range 2 to 4), and the balloon sizes used were 22.0 +/- 1.8 mm (range 20 to 25 mm). fourteen patients (52%) required upsizing of the initial balloon suggested by tee; rapid pacing duration was 8 +/- 1.3 s (range 6 to 11 s). no change in aortic insufficiency or hemodynamic instability occurred with bav. fifteen patients (56%) received a 23-mm thv; 12 patients a 26-mm thv. no coronary occlusion, annular damage, or thv embolization occurred. paravalvular leak wa

Who reads Use of Balloon Aortic Valvuloplasty to Size the Aortic Annulus Before Implantation of a Balloon-Expandable Transcatheter Heart Valve?

It is typically read by researchers, students, and practitioners in Medicine.

Author
Vasilis C. Babaliaros; Zahid Junagadhwalla; Stamatios Lerakis; Vinod Thourani; David Liff; Edward Chen; Thomas Vassiliades; Clay Chappell; Nathan Gross; Ateet Patel; Sharon Howell; Jacob T. Green; Emir Veledar; Robert Guyton; Peter C. Block
Publisher
American College of Cardiology; Elsevier ; Elsevier BV (ISSN 1936-8798)
Published
2010
Language
EN
Field
Medicine (Health Sciences)

More by Vasilis C. Babaliaros; Zahid Junagadhwalla; Stamatios Lerakis; Vinod Thourani; David Liff; Edward Chen; Thomas Vassiliades; Clay Chappell; Nathan Gross; Ateet Patel; Sharon Howell; Jacob T. Green; Emir Veledar; Robert Guyton; Peter C. Block

Browse all works by Vasilis C. Babaliaros; Zahid Junagadhwalla; Stamatios Lerakis; Vinod Thourani; David Liff; Edward Chen; Thomas Vassiliades; Clay Chappell; Nathan Gross; Ateet Patel; Sharon Howell; Jacob T. Green; Emir Veledar; Robert Guyton; Peter C. Block