1. The document describes procedures for inspecting diodes, including using either a digital or analog circuit tester. The digital tester checks the diode range and indicated value, while the analog tester checks resistance range and needle swing direction. 2. For a normal diode, the analog tester needle will not swing when probes are on anode to cathode, but will swing when reversed. A shorted diode causes the needle to swing in both directions. 3. The inspection determines if diodes are good or defect