Pipeline Dew Point Detector Instructions by Tahir Mehmood is a document available to read on EtoBox.
This document provides instructions for using the Gastec No. 6LP Pipeline Dew Point Detector Tube. The tube is used to measure humidity levels in natural gas pipelines between 3-40 LB/MMCF. It works by detecting a color change caused by a chemical reaction between water vapor and reagents in the tube. The instructions describe handling and operating the tube safely, taking accurate measurements, making corrections for temperature and pressure, and properly disposing of or storing the tube.