Pipe Strain Check Procedure Guide by kamal arab is a document available to read on EtoBox.
This procedure outlines how to check for pipe strain on horizontally and vertically mounted machines using dial indicators. For horizontal machines, two dial indicators are placed on the shaft to measure movement as flange bolts are tightened in three steps up to full torque. Readings after full tightening should not exceed 50 microns to avoid pipe strain. For vertical machines, the orientation of the machine relative to the pipe is specified for checking.