CFD Study on Engine Water Jacket Ribs by Niharika is a document available to read on EtoBox.
The document summarizes a computational fluid dynamics (CFD) analysis comparing the cooling performance of an internal combustion engine water jacket with and without added ribs. The CFD analysis found that: 1) Adding ribs near the combustion chamber altered the cooling pattern inside the water jacket, but resulted in only minor differences in temperature, turbulence, velocity, and eddy viscosity compared to the original design. 2) Near the cylinders, temperatures were generally similar between the design