Cálculo de Zapata Aislada ACI 318M-08 by Arovet Irineo is a document available to read on EtoBox.

This document contains calculations for the design of an isolated foundation, providing input parameters, load cases, approximate base dimensions, footing depth, net ultimate soil pressure profiles, and checks for contact pressure, overturning, sliding, wide beam shear, and punching shear. The calculations determine that the design is not stable against overturning or sliding. Punching shear capacity is also exceeded for some load cases.