Balkan Kalıp Sample Measurement Report by gunaydin donmez is a document available to read on EtoBox.

This document is a measurement report for part number 7185-4075-06. It details the nominal and tolerance values for 18 dimensions of the part and the results of 5 measurements for each dimension. For dimensions 13-1 and 13-2, the measurements deviated outside the acceptable tolerance, with results of -0.68 and -0.07 respectively. The rest of the dimensions were within tolerance. The part failed quality control due to the deviations in dimensions 13-1 and 13-2.