This document provides specifications for abandoning sewer mains, including cutting and capping existing sewers, filling with flowable fill, and demolition and preparation requirements. It outlines submittal processes, approved plug and fill materials, and execution methods for abandoning pipes and structures. Pipes under roads will be filled completely with flowable fill meeting strength, shrinkage, and density specifications, while other structures like manholes will be partially filled with flowable fill