Opening book details…
Can I read SAP2000 Column Design Analysis on EtoBox?
SAP2000 Column Design Analysis by halil aydın is a document available to read on EtoBox.
What is SAP2000 Column Design Analysis about?
This document summarizes the column section design of element 1812 from a SAP2000 analysis. The column has a diameter of 800 mm and is subjected to an axial load of 28849 kN with biaxial bending moments of 2182184 kN-mm and -13055990 kN-mm. The minimum required capacities are checked against. Shear forces are also analyzed for the major and minor directions.
- Author
- halil aydın
- Language
- EN