Can I read Submersible Motor Cooling Guidelines on EtoBox?

Submersible Motor Cooling Guidelines by JEANXITOMAZNA is a document available to read on EtoBox.

What is Submersible Motor Cooling Guidelines about?

All Franklin Electric submersible motors are designed to operate at maximum service factor horsepower in water temperatures up to 86°F with certain minimum water flow rates. Higher water temperatures require increased flow to maintain safe motor temperatures. An 8" SEVERE DUTY model can operate up to 90°C with 0.5 ft/sec flow. When installed in a casing much larger than the motor, stagnant water can rise in temperature, shortening motor life. A flow inducer uses a PVC sleeve to force water flow around the m