Skip to content

Opening book details…

Can I read PRU Heater Sizing Calculations on EtoBox?

PRU Heater Sizing Calculations by tinopranoto is a document available to read on EtoBox.

What is PRU Heater Sizing Calculations about?

This document provides sizing calculations for a pressure regulator heater. It calculates the required heat output (in kW) for various inlet pressures to maintain a target outlet temperature of 30°C. The maximum inlet pressure is 250 barg and the required gas flow rate is 30,000 Nm3/hr. The calculations show that an inlet pressure of 250 barg requires a total heater capacity of 895.48 kW, while an inlet pressure of 50 barg or less requires 126.61 kW.

Author
tinopranoto
Language
EN

More by tinopranoto

Browse all works by tinopranoto