The Type of Aortic Cannula and Membrane Oxygenator Affect the Pulsatile Waveform Morphology Produced by a Neonate-Infant Cardiopulmonary Bypass System In Vivo by Akif Ündar; Andrew J. Lodge; Casey W. Daggett; Thomas M. Runge; Ross M. Ungerleider; John H. Calhoon is a Medicine article available to read on EtoBox.

What is The Type of Aortic Cannula and Membrane Oxygenator Affect the Pulsatile Waveform Morphology Produced by a Neonate-Infant Cardiopulmonary Bypass System In Vivo about?

Although the debate still continues over the effectiveness of pulsatile versus nonpulsatile perfusion, it has been clearly proven that there are several significant physiological benefits of pulsatile perfusion during cardiopulmonary bypass (CPB) compared to nonpulsatile perfusion. However, the components of the extracorporeal circuit have not been fully investigated regarding the quality of the pulsatility. In addition, most of these results have been gathered from adult patients, not from neonates and infants. We have designed and tested a neonate‐infant pulsatile CPB system using 2 different types of 10 Fr aortic cannulas and membrane oxygenators in 3 kg piglets to evaluate the effects of these components on the pulsatile waveform produced by the system. In terms of the methods, Group 1 (Capiox 308 hollow‐fiber membrane oxygenator and DLP aortic cannula with a very short 10 Fr tip [n =2]) was subjected to a 2 h period of normothermic pulsatile CPB with a pump flow rate of 150 ml/kg/min. Data were obtained at 5, 30, 60, 90, and 120 min of CPB. In Group 2 (Capiox 308 hollow‐fiber membrane oxygenator and Elecath aortic cannula with a very long 10 Fr tip [n =7]) and Group 3 (Cobe VP

Who reads The Type of Aortic Cannula and Membrane Oxygenator Affect the Pulsatile Waveform Morphology Produced by a Neonate-Infant Cardiopulmonary Bypass System In Vivo?

It is typically read by researchers, students, and practitioners in Medicine.

Author
Akif Ündar; Andrew J. Lodge; Casey W. Daggett; Thomas M. Runge; Ross M. Ungerleider; John H. Calhoon
Publisher
John Wiley and Sons; Wiley (Blackwell Publishing); Blackwell Publishing Inc.; Wiley (ISSN 0160-564X)
Published
1998
Language
EN
Field
Medicine (Health Sciences)

More by Akif Ündar; Andrew J. Lodge; Casey W. Daggett; Thomas M. Runge; Ross M. Ungerleider; John H. Calhoon

Browse all works by Akif Ündar; Andrew J. Lodge; Casey W. Daggett; Thomas M. Runge; Ross M. Ungerleider; John H. Calhoon