About this document
Knife Plate Connection in HSS Bracing by ebi is a document available to read on EtoBox.
The document describes a study that tested knife plate connections used in steel structures, varying the knife plate thickness, length of the gap between the plate and slot, HSS wall thickness, and weld length to determine their effects on fatigue life, and instrumented some specimens to investigate stress distribution under loading. Specimens with knife plate thicknesses of 12mm and 18mm, HSS wall thicknesses of 4.8mm and 6.4mm, gap lengths from 0-200mm, and weld lengths of 150mm were cyclically loaded in
- Author
- ebi
- Language
- EN