Heat Transfer. Heat Loss From A Pipe in An Oudoor Location (This File Is in Working) by vyrgo is a document available to read on EtoBox.

This document defines a routine to calculate the heat loss rate of a carbon steel pipe in an outdoor location. The pipe has a diameter of 20 inches, is 40 feet long, insulated with 50mm of polyamid foam, and contains superheated steam at 225°C. The ambient air and surrounding surfaces are at 2°C. Input data on pipe dimensions, insulation properties, fluid properties and ambient conditions are provided to calculate the heat loss rate using the defined routine.