Opening book details…
Can I read Fuses for voltages exceeding 1000 V a.c.. Expulsion fuses on EtoBox?
Fuses for voltages exceeding 1000 V a.c.. Expulsion fuses by British Standards Institute Staff is a reference work available to read on EtoBox.
What is Fuses for voltages exceeding 1000 V a.c.. Expulsion fuses about?
This standard BS 2692-2:1956 Fuses for voltages exceeding 1000 V a.c. is classified in these ICS categories: 29.120.50 Fuses and other overcurrent protection devices This British Standard relates to fuses for use indoors or outdoors on alternating current systems having line-to-line voltages above 1 000 volts at a frequency of 50 cycles per second, and with breaking-capacities corresponding to three-phase values from25 MVA to 750 MVA for power fuses and from50 MVA to 2 500 MVA for voltage-transformer fuses (or equivalent values for other systems). In general, these fuses are suitable for short-circuit protection only, leaving other devices for protection against over-currents. The requirements of this standard apply to fuses for use in air and to fuses for use immersed in oil. This standard relates only to expulsion fuses. Where fuses depend for their correct operation as fuses on the movement of some component to provide an insulating gap, this feature is considered as part of the fuse operation and comes within the scope of this standard. On the other hand, there are fuse-links that contain tripping devices for initiating the opening of a switch. These fuse-links are required to
Who reads Fuses for voltages exceeding 1000 V a.c.. Expulsion fuses?
It is typically read by working professionals who need an authoritative practice reference.
Common subject areas: medicine, law, business, engineering.
- Author
- British Standards Institute Staff
- Publisher
- BSI British Standards Institution
- Published
- 2007
- Language
- EN
- ISBN
- 9780580025136
- Category
- reference
- Subjects
- Engineering, Electrical & Electronic Engineering, Stem
More by British Standards Institute Staff
Browse all works by British Standards Institute Staff
Similar books
- Specification for A.c. Voltage-operated Earth-leakage Circuit Breakers. — British Standards Institute Staff (2010)
- Shunt Power Capacitors of the Non-self-healing Type for A.c. Systems Having a Rated Voltage Up to and Including 1000 V. Internal Fuses — BSB (1997)
- Live Working. Phase Comparators. Capacitive Type to Be Used for Voltages Exceeding 1 kV A.c. — British Standards Institute Staff (2016)
- Miniature Fuses. User Guide For Miniature Fuses — British Standards Institute Staff (2002)
- Miniature Fuses. Definitions for Miniature Fuses and General Requirements for Miniature Fuse-links — British Standards Institute Staff (2001)
- High-voltage Fuses. Current-limiting Fuses — British Standards Institute Staff (2014)