Skip to content

Opening book details…

Can I read Simultaneous determination of metformin and rosiglitazone in human plasma by liquid chromatography/tandem mass spectrometry with electrospray ionization: Application to a pharmacokinetic study on EtoBox?

Simultaneous determination of metformin and rosiglitazone in human plasma by liquid chromatography/tandem mass spectrometry with electrospray ionization: Application to a pharmacokinetic study by Lu Zhang; Yuan Tian; Zunjian Zhang; Yun Chen is a Chemistry article available to read on EtoBox.

What is Simultaneous determination of metformin and rosiglitazone in human plasma by liquid chromatography/tandem mass spectrometry with electrospray ionization: Application to a pharmacokinetic study about?

A selective and sensitive high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (ESI-MS/MS) method for simultaneous determination of metformin and rosiglitazone in human plasma using phenformin as internal standard (IS) has been first developed and validated. Plasma samples were precipitated by acetonitrile and the analytes were separated on a prepacked Phenomenex Luna 5u CN 100A (150 mm × 2.0 mm I.D.) column using a mobile phase comprised of methanol:30 mM ammonium acetate pH 5.0 (80:20, v/v) delivered at 0.2 ml/min. Detection was performed on a Finnigan TSQ triple-quadrupole tandem mass spectrometer in positive ion selected reaction monitoring (SRM) mode using electrospray ionization. The ion transitions monitored were m/z 130.27 → 71.11 for metformin, m/z 358.14 → 135.07 for rosiglitazone and m/z 206.20 → 105.19 for the IS. The standard curves were linear (r 2 > 0.99) over the concentration range of 5-3000 ng/ml for metformin and 1.5-500 ng/ml for rosiglitazone with acceptable accuracy and precision, respectively. The within-and between-batch precisions were less than 15% of the relative standard deviation. The limit of detection (LOD) of both m

Who reads Simultaneous determination of metformin and rosiglitazone in human plasma by liquid chromatography/tandem mass spectrometry with electrospray ionization: Application to a pharmacokinetic study?

It is typically read by researchers, students, and practitioners in Chemistry.

Author
Lu Zhang; Yuan Tian; Zunjian Zhang; Yun Chen
Publisher
Elsevier Science; Elsevier ; Elsevier BV (ISSN 1873-376X)
Published
2007
Language
EN
Field
Chemistry (Physical Sciences)

More by Lu Zhang; Yuan Tian; Zunjian Zhang; Yun Chen

Browse all works by Lu Zhang; Yuan Tian; Zunjian Zhang; Yun Chen