Weld Design Calculations for I-Shape by Travis C. Smith, P.E. is a document available to read on EtoBox.

The document provides calculations to determine the minimum weld size for an I-shape weld type 10. Key parameters like material strength, beam dimensions, and applied loads are given. Equations for section properties, stresses, and minimum weld size are shown based on Allowable Stress Design (ASD) and Load Resistance Factor Design (LRFD) codes. The minimum weld size is calculated as 0.193 inches based on ASD/LRFD codes and 0.211 inches based on additional TVA criteria.