W5C Flaw Detection Report by Sanjaya Perera is a document available to read on EtoBox.
This flaw detecting report from July 31, 2015 documents the detection of a flaw on a part during non-destructive testing. The flaw was found 89.4mm from the test surface, had a projection of 84.0mm and depth of 1.4mm using an MFD500B instrument with a 4MHz dual element probe.