1. The document provides load calculations for a bridge pier including dead loads, live loads, forces from water current, temperature effects, and braking loads. 2. Total dead load on the pier is 1453.76 kN. Live load reactions were calculated as 998.5 kN and 1264.85 kN for single and double span loading. 3. Maximum moment on the pier from water current is 177.99 kNm for 0 degrees and 157.17 kNm for 20 degrees. Braking loads result in a maximum moment of 2936.33 kNm.