Skip to content

Opening book details…

About this document

Capacitive Level Sensor Lab Experiment by Hardik Agravatt is a document available to read on EtoBox.

The document describes an experiment to study and calibrate a capacitive level sensor for liquid level measurement. It explains that a capacitive level sensor works by measuring the capacitance between a probe and the tank wall, which changes based on the dielectric material (liquid) between them. The experiment involves installing a SAPCON TRANSlite capacitive level sensor on a tank, wiring it to a current to voltage converter, varying the liquid level, and recording the sensor output voltages at minimum a

Author
Hardik Agravatt
Language
EN