Opening book details…
Can I read Radiological protection -- Minimum criteria for electron paramagnetic resonance (EPR) spectroscopy for retrospective dosimetry of ionizing radiation -- Part 1: General principles on EtoBox?
Radiological protection -- Minimum criteria for electron paramagnetic resonance (EPR) spectroscopy for retrospective dosimetry of ionizing radiation -- Part 1: General principles by ISO/TC 85/SC 2 Radiological protection is a reference work available to read on EtoBox.
What is Radiological protection -- Minimum criteria for electron paramagnetic resonance (EPR) spectroscopy for retrospective dosimetry of ionizing radiation -- Part 1: General principles about?
The primary purpose of ISO 13304-1:2013 is to provide minimum acceptable criteria required to establish procedure of retrospective dosimetry by electron paramagnetic resonance spectroscopy and to report the results. The second purpose is to facilitate the comparison of measurements related to absorbed dose estimation obtained in different laboratories. ISO 13304-1:2013 covers the determination of absorbed dose in the measured material. It does not cover the calculation of dose to organs or to the body. It covers measurements in both biological and inanimate samples, and specifically:. based on inanimate environmental materials, usually made at X-band microwave frequencies (8 GHz to 12 GHz);. in vitro tooth enamel using concentrated enamel in a sample tube, usually employing X-band frequency, but higher frequencies are also being considered;. in vivo tooth dosimetry, currently using L-band (1 GHz to 2 GHz), but higher frequencies are also being considered;. in vitro nail dosimetry using nail clippings measured principally at X-band, but higher frequencies are also being considered;. in vivo nail dosimetry with the measurements made at X-band on the intact finger or toe;. in vitro me
Who reads Radiological protection -- Minimum criteria for electron paramagnetic resonance (EPR) spectroscopy for retrospective dosimetry of ionizing radiation -- Part 1: General principles?
It is typically read by working professionals who need an authoritative practice reference.
Common subject areas: medicine, law, business, engineering.
- Author
- ISO/TC 85/SC 2 Radiological protection
- Publisher
- ISO
- Published
- 2013
- Language
- EN
- Category
- reference
More by ISO/TC 85/SC 2 Radiological protection
Browse all works by ISO/TC 85/SC 2 Radiological protection
Similar books
- Radiological Protection Minimum Criteria for Electron Paramagnetic Resonance (EPR) Spectroscopy for Retrospective Dosimetry of Ionizing Radiation Part 2: Ex Vivo Human Tooth Enamel Dosimetry — ИСО
- Radiological Protection -- Performance Criteria for Service Laboratories Performing Biological Dosimetry by Cytogenetics — ISO/TC 85/SC 2 Radiological protection (2014)
- Electrical Insulating Materials. Determination of the Effects of Ionizing Radiation. Radiation Interaction and Dosimetry — JAYNE BROOKS (2013)
- Radiological Protection -- Performance Criteria for Laboratories Using the Cytokinesis Block Micronucleus (CBMN) Assay in Peripheral Blood Lymphocytes for Biological Dosimetry — ISO/TC 85/SC 2 Radiological protection (2014)
- Surface Chemical Analysis. Electron Spectroscopies. Minimum Reporting Requirements for Peak Fitting in X-ray Photoelectron Spectroscopy — British Standards Institute Staff (2015)
- Radiological Protection -- Performance Criteria for Laboratories Using Fluorescence In Situ Hybridization (FISH) Translocation Assay for Assessment of Exposure to Ionizing Radiation — ISO