Opening book details…
Can I read Validation of a novel in vitro assay using ultra performance liquid chromatography–mass spectrometry (UPLC/MS) to detect and quantify hydroxylated metabolites of BDE-99 in rat liver microsomes on EtoBox?
Validation of a novel in vitro assay using ultra performance liquid chromatography–mass spectrometry (UPLC/MS) to detect and quantify hydroxylated metabolites of BDE-99 in rat liver microsomes by Claudio A. Erratico; András Szeitz; Stelvio M. Bandiera is a Chemistry article available to read on EtoBox.
What is Validation of a novel in vitro assay using ultra performance liquid chromatography–mass spectrometry (UPLC/MS) to detect and quantify hydroxylated metabolites of BDE-99 in rat liver microsomes about?
The purpose of this study was to develop and validate an ultra performance liquid chromatography-mass spectrometry (UPLC/MS) method to investigate the hepatic oxidative metabolism of 2,2',4,4',5-pentabromodiphenyl ether (BDE-99), a widely used flame retardant and ubiquitous environmental contaminant. Hydroxylated metabolites were extracted using liquid-to-liquid extraction, resolved on a C18 column with gradient elution and detected by mass spectrometry in single ion recording mode using electrospray negative ionization. The assay was validated for linearity, accuracy, precision, limit of quantification, range and recovery. Calibration curves were linear (R2 > or = 0.98) over a concentration range of 0.010-1.0 microM for 4-OH-2,2',3,4',5-pentabromodiphenyl ether (4-OH-BDE-90), 5'-OH-2,2',4,4',5-pentabromodiphenyl ether (5'-OH-BDE-99) and 6'-OH-2,2',4,4',5-pentabromodiphenyl ether (6'-OH-BDE-99), and a concentration range of 0.0625-12.5 microM for 2,4,5-tribromophenol (2,4,5-TBP). Inter- and intra-day accuracy values ranged from -2.0% to 6.0% and from -7.7% to 7.3%, respectively, and inter- and intra-day precision values ranged from 2.0% to 8.5% and from 2.2% to 8.6% (n=6), respecti
Who reads Validation of a novel in vitro assay using ultra performance liquid chromatography–mass spectrometry (UPLC/MS) to detect and quantify hydroxylated metabolites of BDE-99 in rat liver microsomes?
It is typically read by researchers, students, and practitioners in Chemistry.
- Author
- Claudio A. Erratico; András Szeitz; Stelvio M. Bandiera
- Publisher
- Elsevier Science; Elsevier ; Elsevier BV (ISSN 1873-376X)
- Published
- 2010
- Language
- EN
- Field
- Chemistry (Physical Sciences)
More by Claudio A. Erratico; András Szeitz; Stelvio M. Bandiera
Browse all works by Claudio A. Erratico; András Szeitz; Stelvio M. Bandiera