APU Shutdown Troubleshooting Guide by Eduardo Fabian is a document available to read on EtoBox.
The document provides fault isolation steps for an APU shutdown during start or normal operation on a Fokker 50/60 aircraft. The steps include checking indications on the GEN LOAD and ESU displays, and performing resistance checks and replacements of components like the ESU, MPU, and FCU. If the fault persists after following these steps, a borescope inspection and compressor wash may be required.