1) An infrared scan of a pump detected higher than expected heat in the coupler, indicating a potential problem. 2) Vibration analysis confirmed mechanical looseness and misalignment in the coupler. 3) Inspection found damage to the flexible spider in the coupler, which was causing contact between coupler halves and increased heat and vibration. Replacing the coupler avoided potential failure.