1. The document describes the process of creating a distance amplitude correction (DAC) curve to compensate for sound energy loss over distance in an ultrasound test. 2. The procedure involves positioning an ultrasound probe at set distances from a side drilled hole and adjusting the gain to mark echo peaks at specific screen heights. 3. Gains are adjusted down in 6dB increments for multiple probe positions to generate data points, which are then connected to form the DAC curve graphing the relationship