1. A directional coupler and power meters were used to measure the incident and reflected power from different loads connected to a waveguide. 2. The reflection coefficient was calculated from the ratio of reflected to incident power, and return loss was determined from the reflection coefficient. 3. An SWR meter with an amplitude modulated signal was used to measure return loss for different loads by varying the attenuation and recording the relative signal level. This was used to calculate reflection c