About this document
Pipe Culvert Design Calculations Guide by Rohit Kumar Behera is a document available to read on EtoBox.
This document discusses equations for calculating pipe culvert design under inlet control or outlet control conditions. Under inlet control, the flow rate is controlled by conditions at the inlet and can be calculated using an equation that relates headwater depth, diameter, flow rate, slope, and inlet type. Under outlet control, the flow rate is controlled by conditions at the outlet and friction loss, and can be calculated using the Manning equation relating head loss, diameter, roughness, length, and los
- Author
- Rohit Kumar Behera
- Language
- EN