Skip to content

Opening book details…

Can I read Exergy Analysis of Binary Geothermal Plant on EtoBox?

Exergy Analysis of Binary Geothermal Plant by HassanKM is a document available to read on EtoBox.

What is Exergy Analysis of Binary Geothermal Plant about?

This document provides an exergy analysis of a 12.4 MW dual-level binary geothermal power plant in Northern Nevada, USA. The plant uses geothermal fluid at 163°C to evaporate isopentane in vaporizers. Exergy destruction throughout the plant is quantified and the major sites of exergy destruction are determined to be the condenser, brine reinjection, turbine-pump losses, and preheater-vaporizer losses. The exergetic efficiency of the plant is calculated to be 29.1-34.2% compared to thermal efficiencies of 5.