Opening book details…
Can I read Standard Details for RCPC Culvert Design on EtoBox?
Standard Details for RCPC Culvert Design by PolAngeles is a document available to read on EtoBox.
What is Standard Details for RCPC Culvert Design about?
The document contains details of proposed drainage structures including a temporary road (TR2) and reinforced concrete pipes (RCPC). It includes the required discharge capacity, pipe diameter, cross-sectional area, and design discharge of TR2 which is a 20-year return period structure requiring a discharge capacity of 37 cubic meters per second with 10 pipes of 1070mm diameter and a total cross-sectional area of 46.25 square meters. Engineering drawings show plan and sectional details of the embankment, com
- Author
- PolAngeles
- Language
- EN