Compression Test Results for Insulation Foam by 07200 is a document available to read on EtoBox.

The document details a compression test conducted on pre-insulated duct samples by Ms. Anuthida Uranjit on December 19, 2567. It includes parameters such as temperature, humidity, and machine specifications, along with the compressive strength and modulus results for multiple samples. The average compressive strength was found to be 1924.69 N with a standard deviation of 99.30 N.