Can I read Initial Load Test Report for Pile TP-6 on EtoBox?

Initial Load Test Report for Pile TP-6 by ram.deshpande is a document available to read on EtoBox.

What is Initial Load Test Report for Pile TP-6 about?

The document provides a report on the initial vertical load test conducted on Test Pile TP-6 that was part of piling works for a project in Gopalpur, Odisha, India. Key details include: - The test pile was a 600mm diameter bored cast in situ pile with a length of 22.15m. - A maximum test load of 655MT was applied using incremental and decremental loading. - Observations found a gross settlement of 11.97mm and net settlement of 6.01mm under the maximum test load. - Based on load-settlement criteria in

Author
ram.deshpande
Language
EN

More by ram.deshpande