The document presents an experimental analysis of a semi-open impeller used in a Pump as Turbine (PAT) for low-cost electric power generation, particularly in rural areas. The study compares the performance of open, semi-open, and closed impellers, concluding that while open impellers generate more power, semi-open impellers are more durable and efficient, with the 2 mm blade thickness producing approximately 36% more power than the original closed impeller. The research highlights the importance of impelle