Skip to content

Opening book details…

Can I read Initial radiometric calibration of the High-Resolution EUV Imager ($\textrm{HRI}_\textrm{EUV}$) of the Extreme Ultraviolet Imager (EUI) instrument onboard Solar Orbiter on EtoBox?

Initial radiometric calibration of the High-Resolution EUV Imager ($\textrm{HRI}_\textrm{EUV}$) of the Extreme Ultraviolet Imager (EUI) instrument onboard Solar Orbiter by Gissot, S.; Auchère, F.; Berghmans, D.; Giordanengo, B.; BenMoussa, A.; Rebellato, J.; Harra, L.; Long, D.; Rochus, P.; Schühle, U.; Cuadrado, R. Aznar; Delmotte, F.; Dumesnil, C.; Gottwald, A.; Halain, J. -P.; Heerlein, K.; Hellin, M. -L.; Hermans, A.; Jacques, L.; Kraaikamp, E.; Mercier, R.; Rochus, P.; Smith, P. J.; Teriaca, L.; Verbeeck, C. is a scholarly article available to read on EtoBox.

What is Initial radiometric calibration of the High-Resolution EUV Imager ($\textrm{HRI}_\textrm{EUV}$) of the Extreme Ultraviolet Imager (EUI) instrument onboard Solar Orbiter about?

The $\textrm{HRI}_\textrm{EUV}$ telescope was calibrated on ground at the Physikalisch-Technische Bundesanstalt (PTB), Germany's national metrology institute, using the Metrology Light Source (MLS) synchrotron in April 2017 during the calibration campaign of the Extreme Ultraviolet Imager (EUI) instrument onboard the Solar Orbiter mission. We use the pre-flight end-to-end calibration and component-level (mirror multilayer coatings, filters, detector) characterization results to establish the beginning-of-life performance of the $\textrm{HRI}_\textrm{EUV}$ telescope which shall serve as a reference for radiometric analysis and monitoring of the telescope in-flight degradation. Calibration activities at component level and end-to-end calibration of the instrument were performed at PTB/MLS synchrotron light source (Berlin, Germany) and the SOLEIL synchrotron. Each component optical property is measured and compared to its semi-empirical model. This pre-flight characterization is used to estimate the parameters of the semi-empirical models. The end-to-end response is measured and validated by comparison with calibration measurements, as well as with its main design performance requirem

Author
Gissot, S.; Auchère, F.; Berghmans, D.; Giordanengo, B.; BenMoussa, A.; Rebellato, J.; Harra, L.; Long, D.; Rochus, P.; Schühle, U.; Cuadrado, R. Aznar; Delmotte, F.; Dumesnil, C.; Gottwald, A.; Halain, J. -P.; Heerlein, K.; Hellin, M. -L.; Hermans, A.; Jacques, L.; Kraaikamp, E.; Mercier, R.; Rochus, P.; Smith, P. J.; Teriaca, L.; Verbeeck, C.
Published
2023
Language
EN

More by Gissot, S.; Auchère, F.; Berghmans, D.; Giordanengo, B.; BenMoussa, A.; Rebellato, J.; Harra, L.; Long, D.; Rochus, P.; Schühle, U.; Cuadrado, R. Aznar; Delmotte, F.; Dumesnil, C.; Gottwald, A.; Halain, J. -P.; Heerlein, K.; Hellin, M. -L.; Hermans, A.; Jacques, L.; Kraaikamp, E.; Mercier, R.; Rochus, P.; Smith, P. J.; Teriaca, L.; Verbeeck, C.

Browse all works by Gissot, S.; Auchère, F.; Berghmans, D.; Giordanengo, B.; BenMoussa, A.; Rebellato, J.; Harra, L.; Long, D.; Rochus, P.; Schühle, U.; Cuadrado, R. Aznar; Delmotte, F.; Dumesnil, C.; Gottwald, A.; Halain, J. -P.; Heerlein, K.; Hellin, M. -L.; Hermans, A.; Jacques, L.; Kraaikamp, E.; Mercier, R.; Rochus, P.; Smith, P. J.; Teriaca, L.; Verbeeck, C.