The document outlines the load deration for engines D2862LE231 and D2862LE233 at two different speeds (1500 min-1 and 1800 min-1) with specified power outputs at test benches in Nürnberg. It notes that power is reduced by the EDC at ambient temperatures up to 25 °C and requires additional reductions from the operator at temperatures above 25 °C. The document includes details on power ratings and the impact of ambient temperature and altitude.