Furuno PM-30 Radar Performance Test Guide by LB is a document available to read on EtoBox.
This document provides instructions for adjusting the Furuno PM-30 Performance Monitor during installation. It describes: 1. Confirming the front cover is securely fastened to prevent microwave leakage. 2. Removing caps from the receiving and transmitting attenuators. 3. Setting up the radar system and activating the Performance Monitor. 4. Adjusting the receiving attenuator so the innermost arcs appear at a range of 12 ±0.5 nm. 5. Adjusting the transmitting attenuator so the outermost arc is sligh