Opening book details…
Can I read Radiological protection -- X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy -- Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV on EtoBox?
Radiological protection -- X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy -- Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV by ISO is a reference work available to read on EtoBox.
What is Radiological protection -- X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy -- Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV about?
Foreword 0 Introduction 0 1 Scope 0 2 Normative references 0 3 Terms and definitions 0 4 Standard instrument 0 4.1 General 0 4.2 Calibration of the standard instrument 0 4.3 Energy dependence of the response of the standard instrument 0 5 Conversion from the measured quantity air kerma, Ka, to the required phantom related measuring quantity 0 5.1 General 0 5.2 Determination of conversion coefficients 0 5.2.1 General 0 5.2.2 Calculation of conversion coefficients from spectral fluence 0 5.3 Validation of reference fields and of listed conversion coefficients using dosimetry 0 6 Direct calibration of the reference field in terms of the required phantom related measuring quantity 0 7 Measurement procedures applicable to ionization chambers 0 7.1 Geometrical conditions 0 7.2 Chamber support and stem scatter 0 7.3 Location and orientation of the standard chamber 0 7.4 Measurement corrections 0 7.4.1 General 0 7.4.2 Corrections for air temperature, pressure and humidity variation from reference calibration conditions 0 7.4.3 Corrections for radiation-induced leakage, including ambient radiation 0 7.4.4 Incomplete ion collection 0 7.4.5 Beam non-uniformity 0 8 Additional procedures and pr
Who reads Radiological protection -- X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy -- Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV?
It is typically read by working professionals who need an authoritative practice reference.
Common subject areas: medicine, law, business, engineering.
- Author
- ISO
- Language
- EN
- Category
- reference
More by ISO
Similar books
- Radiological protection -- Characteristics of reference pulsed radiation -- Part 1: Photon radiation
- Radiological Protection -- Monitoring and Internal Dosimetry for Specific Materials -- Part 1: Inhalation of Uranium Compounds
- Dosimetry for Exposures to Cosmic Radiation in Civilian Aircraft Part 1: Conceptual Basis for Measurements — ISO
- Reference Radiation Fields for Radiation Protection -- Definitions and Fundamental Concepts — ISO/TC 85/SC 2 Radiological protection (2012)
- Radiation Protection -- Performance Criteria for Radiobioassay — ISO/TC 85/SC 2 Radiological protection (2010)
- Radiological Protection Minimum Criteria for Electron Paramagnetic Resonance (EPR) Spectroscopy for Retrospective Dosimetry of Ionizing Radiation Part 2: Ex Vivo Human Tooth Enamel Dosimetry — ИСО