Ohmic Losses in Tesla Transformers by Marjan Blagojevic is a document available to read on EtoBox.
This document presents an analysis of ohmic losses in Tesla transformers with an open magnetic-core configuration, introducing a novel coaxial design for the primary side that utilizes a mechanically controlled spark gap. The study estimates series parameters and ohmic losses, revealing that parasitic and contact resistances significantly impact voltage gain, with experiments showing a voltage drop of 8.2% due to increased parasitic resistance. The findings suggest that optimizing contact resistance below 1
- Author
- Marjan Blagojevic
- Language
- EN